INSTALLATION INSTRUCTIONS
Caution: Switch off the electric source before installing the thermostat. We recommend that the installation
should be performed by a trained personnel.
Select a suitable location for the AURATON.
The location of the thermostat can greatly affect
its performance. If it is located at where circulate air
cannot reach, or exposed to direct sun light, it will not
adjust the room temperature properly.
To ensure proper operation, the thermostat should
be installed at an inside wall with freely circulating air.
Find a place where your family usually occupied.
Avoid close to some heat generating appliance
(e.g. TV, heater, refrigerator) or exposed to direct sun
light. Do not install near a door where the thermostat
will suffer from vibration.
Wiring.
Wiring terminals are at the back of the thermostat. Press down the terminal cover, you can find three
terminals which labelled COM, NO and NC. It is a typical single-pole, double throw (SPDT) contact. In most
COM and NO are used.
Mounting the thermostat.
Use the template provided, drill two 6mm holes on the wall. Insert the wall anchors and tighten the left
screw with 3mm clearance. Fix the thermostat by putting it over the screwhead and slide it rightward (note
the keyhole like opening at the back of the thermostat). Tighten the remain screw to lock it in place.
Note:
If the wall is made of wood, there is no need to use the wall anchors. Drill two 2.7mm holes instead of
6mm.